The PROACT Trial - INR 1.5-2.0 for mechanical aortic valves [1]
the Prospective Randomized On–X Anticoagulation Clinical Trial (PROACT) tests the safety of less aggressive anticoagulation than is recommended by ACC/AHA guidelines after implantation of an approved bileaflet mechanical valve. INR may be safely maintained between 1.5–2.0 after AVR with this approved bileaflet mechanical prosthesis. With low–dose aspirin, this resulted in significantly lower risk of bleeding, without significant increase in TE.