Achieving absolute intraoperative hemostasis and perfect anatomical symmetry remains a critical technical challenge during valve-sparing aortic root replacement, also known as the David procedure. The traditional technique relies on a continuous running suture to secure the native sinus rim to the synthetic vascular graft, serving as the primary hemostatic line. However, tensioning a continuous suture can occasionally lead to localized tissue distortion, minor bleeding zones, or microtears in the fragile aortic wall.
Methods
This video provides a comprehensive, step-by-step demonstration of an institutional modification focused on the second hemostatic suture line. Following standard proximal dissection of the aortic root and the placement of the basal suture line, the three commissures were suspended and fixed inside the graft.
Instead of proceeding with the classic continuous running suture along the perimeter of the sinuses of Valsalva, the authors utilized elective, separate horizontal mattress 2-0 coated polyester sutures with polytetrafluoroethylene (PTFE) pledgets. A key technical nuance of this approach is that the pledgets must be placed strictly on the inside of the aortic root to protect the native tissue. On the outside of the vascular graft, the use of pledgets is optional, as the sutures can be tied directly onto the synthetic fabric with identical structural integrity.
Results
This refined technique evolved from a localized reinforcement strategy into a systematic, routine approach. It has been successfully implemented in 23 consecutive patients at the authors’ institution, becoming the standard protocol for all David procedures.
This suture modification completely eliminates the risk of tissue tearing, or cheese-wiring, and ensures a highly symmetrical, anatomically precise alignment of the aortic root within the graft without any tissue wrinkling.
Key Takeaway
Although long-term evidence is still accumulating, this modification offers a reproducible and highly effective technical solution that subjectively provides a far superior intraoperative hemostatic seal during complex aortic root reconstruction.
References
- de Kerchove L, Mosala Nezhad Z, Boodhwani M, El Khoury G. How to perform valve sparing reimplantation in a tricuspid aortic valve. Ann Cardiothorac Surg 2013;2(1):105-112. doi: 10.3978/j.issn.2225-319X.2013.01.16