This report provides long-term outcome data on the Perimount valve implanted in the mitral position in patients 65 years of age or less. The expected valve durability was 14.2 years, which compares favourably with other prosthetic valves. Long term mortality was considered valve-related in 1.3% per valve-years, with an overall mortality of 4% per valve-years. The authors provide useful predictions of valve degeneration rates and need for reoperative surgery.
You are here:
Bioprosthetic Mitral Valve Replacement in Patients Aged 65 Years or Younger: Long-Term Outcomes With the Carpentier–Edwards PERIMOUNT Pericardial Valve
Submitted by: Benjamin Bidstrup
Source: European Journal of Cardio-Thoracic Surgery
Source URL: https://doi.org/10.1093/ejcts/ezy029
Keywords:
Author(s): Thierry Bourguignon, Fabien Espitalier, Clémence Pantaleon, Emmanuelle Vermes, Jean Marc El-Arid, Claudia Loardi ,Elias Karam, Pascal Candolfi, Fabrice Ivanes, Michel Aupart