Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch [1]
Suture techniques were compared for prosthesis-patient mismatch among groups who underwent aortic valve replacement and had a small annulus. Nonpledget mattress sutures performed better than pledget mattress sutures and figure-of-8 nonpledget sutures.