You are here:

Annular Rupture Repair After TAVR

This article is part of CTSNet’s series, Perfecting TAVR Removal | Skills Sharpening With Vince Gaudiani. CTSNet Senior Editor Dr. Vince Gaudiani presents nine surgical videos on the technical aspects of aortic valve replacement after TAVR. This series will conclude in three live learning roundtable events, scheduled at three different times to accommodate participants in multiple regions of the world. 

In this video, the patient underwent transcatheter aortic valve replacement (TAVR), during which a pericardial collection was identified. The patient was initially stable, but after two days and further imaging, a contained aortic annulus rupture was diagnosed, and he was urgently taken to the operating room.

The removal of the new TAVR was relatively straightforward, utilizing the handlebar mustache technique, scissors, and a wire cutter.  The annulus was debrided, and the aortic rupture was found under the left main stem.

A Dacron patch was placed over the defect, followed by pledgeted 2-0 sutures for the 25 mm valve over the patch, and the operation was completed.


Disclaimer

The information and views presented on CTSNet.org represent the views of the authors and contributors of the material and not of CTSNet. Please review our full disclaimer page here.

Add Comments

Vimeo 610 views on Vimeo

CITATION

Gaudiani V, Tsau P. Annular Rupture Repair After TAVR. October 2025. doi:10.25373/ctsnet.30356218